EM-WPA Series

External Emergency Driver

The EM-WPA series emergency LED driver from is for field and factory installation that allows any Sunled 0-10V dimmable fixture to be used for both normal and emergency operation.

The unit contains a battery charger in IP67 sealed polycarbornate enclosure and inverter that operates a load of 8W, 18W or 30W with constant power at a rated output voltage of 170VDC. The patented constant power circuitry of the module maintains uninterrupted illumination levels during power failure

 

Armour logos3

 
 



  1. PRODUCT VARIATIONS
  2. FEATURES
  3. SELF DIAGNOSTIC
  4. OPERATION
  5. SPECIFICATIONS
  6. APPLICATIONS
 
Product Code

Example EM-WPA cat. 18.WW

 MODEL NO WATTAGE TEST SWITCH
EM-WPA 8 8W/Up to 100W Driver WW Wired
18 18W/Up to 200W Driver WL 2.4GHz Remote
30 30W/Up to 300W Driver
 
NOTES
¹ The emergency driver is not compatible with non-dimmable fixtures when the driver wattages is less than the fixture wattage. 
 
Features
 
  • UL 924 Listed for U.S. and Canada
  • Constant power output in emergency mode
  • One piece design with IP67 vandal resistant polycarbonate housing
  • Long-life, maintenance-free, high temperature recyclable Lithium Battery
  • Rated for use in plenums, damp locations, enclosed and gasketed fixtures
 
Self Diagnostic
 
The integrated self-diagnostic circuitry will automatically conduct 1 monthly 30 second and annual 90 minute tests to verify proper emergency capability per life safety code requirements NFPA 101 Life Safety Code outlines the following schedule:
 
Monthly
During AC mode, the system conducts a 30s self discharge test of the emergency LED driver every 30 days and automatically restores to normal charging after full discharge
 
Annually
During AC mode, the system conducts a 90 minute self discharge test of the emergency led driver every 365 days and automatically restores to normal charging after 30 seconds discharge
 
Operation
 
Normal Supply
During normal AC supply conditions the LED driver load will operate as usual and emergency driver remains in charging mode
 
Emergency Mode
When AC power fails the driver automatically switches to emergency mode, keeping the LED load illuminated at a reduced lumen output for a minimum of 90 minutes. During this time, the indicator will flash slowly (light on for 2 seconds, off for 2 seconds). When AC power is restored, it will return to charging mode and the indicator light remains on
 
Specification
 
Input Voltage: 120-347VAC 50/60Hz
Input Power: 120-347VAC 7W Max
Output Voltage: 170VDC
Output Power: 8,18,30W
Power Factor: 0.85
EMI Radiated/Conducted: FCC Class A Charge and EM Modes
Surge Protection: Line-Neutral 3kV
Emergency Operation: 90 minutes
Charge Time: 24hr Recharge
Ambient Temperature: 0°C to +50°C (30°F to 122°F)
Approval: cUL Listed for Factory and Field Installation
 
 
Applications
 
Canopy fixtures, wallpacks, general external lighting, public spaces, high vandal areas
 

Similar Products

 
Argo1

EM-EMA


Integrated Emergency Driver
Lumina 1

EM-EMB


High Output Emergency Driver
Hawk Eye13

EM-EMS


Split Emergency Driver
Armour Plus13

EM-WPA


External Emergency Driver
Armour Plus13

EM-HBM


Highbay Emergency Driver

Logo Solid Shape Layer 2

100 Duffy Ave. Hicksville NY 11801 — United States +1 917 563 7078